News & Resources

September 21, 2008

New! 1206 Size Fuse, 25 Amps!

First Chip Fuse in a 1206 Package Rated up to 25 Amps

Small Fuse, High Performance for Secondary Circuit Protection

Nu-Way and Schurter have released the first 1206 chip fuse with rated current values up to 25 A. The new slow-blow UST 1206 provides high melting I2t values for impressive inrush withstand performance.

The UST 1206 with characteristics according to UL 248-14 complements Schurter's previously introduced and successful USI 1206 built to IEC 60127-4. The UST 1206 includes current ratings that range from 7 to 25 A with voltage ratings up to 63 VDC and 32 VAC. The device provides a breaking capacity of up to 400 A at a defined voltage. Rated operating temperature is -55°C to +90°C.

The UST 1206 fuse series is a cost-effective solution for applications where high inrush current and on-off cycling is present. It is designed to provide secondary overcurrent protection in power inverters, back lighted DC-AC inverters for monitors, wherein power consumption is high at a low voltage level, e.g. 5 or 12 VDC.

The fuse holds cURus approval. Legend markings on each fuse provide a clear visual identification of rated current. The device is RoHS compliant and is supplied on tape and reel either with 1k or 5k or 15k pieces and is available from stock to 8 weeks. More information on the UST 1206 can be found at www.schurterinc.com/new_fuses.

For more Information Contact: Bill Aldeen
Phone: 847-437-7120   Fax: 847-437-7165
E-mail: baldeen@nuway.net

12

12

September 21, 2008

New! 1206 Size Fuse, 25 Amps!

First Chip Fuse in a 1206 Package Rated up to 25 Amps

Small Fuse, High Performance for Secondary Circuit Protection

Nu-Way and Schurter have released the first 1206 chip fuse with rated current values up to 25 A. The new slow-blow UST 1206 provides high melting I2t values for impressive inrush withstand performance.

The UST 1206 with characteristics according to UL 248-14 complements Schurter's previously introduced and successful USI 1206 built to IEC 60127-4. The UST 1206 includes current ratings that range from 7 to 25 A with voltage ratings up to 63 VDC and 32 VAC. The device provides a breaking capacity of up to 400 A at a defined voltage. Rated operating temperature is -55°C to +90°C.

The UST 1206 fuse series is a cost-effective solution for applications where high inrush current and on-off cycling is present. It is designed to provide secondary overcurrent protection in power inverters, back lighted DC-AC inverters for monitors, wherein power consumption is high at a low voltage level, e.g. 5 or 12 VDC.

The fuse holds cURus approval. Legend markings on each fuse provide a clear visual identification of rated current. The device is RoHS compliant and is supplied on tape and reel either with 1k or 5k or 15k pieces and is available from stock to 8 weeks. More information on the UST 1206 can be found at www.schurterinc.com/new_fuses.

For more Information Contact: Bill Aldeen
Phone: 847-437-7120   Fax: 847-437-7165
E-mail: baldeen@nuway.net

 

  • Ipc member
  • Smta member